Teledyne-lecroy FlexRay Trigger, Decode and Physical Layer Test Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Logiciel Teledyne-lecroy FlexRay Trigger, Decode and Physical Layer Test. Teledyne LeCroy FlexRay Trigger, Decode and Physical Layer Test User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - FLEXRAY

FLEXRAYTRIGGER,DECODE,ANDPHYSICALLAYERTEST  Operator’sManualMARCH,2008

Page 2

The Source Setup information must be defined. The datasheet for your part should contain the information you need to properly setup the FlexRay Tri

Page 3 - TABLE OF CONTENTS

OPERATOR’S MANUAL FlexRay-TDP-OM-E Rev A 11 Cycle Count – The Cycle Count is combined with the Frame ID to enable powerful FlexRay triggering. Th

Page 4 - INTRODUCTION

Error Trigger Setup This set of checkboxes are shown if Error is selected as the trigger type. The errors are broken in to 2 categories, Protocol E

Page 5

OPERATOR’S MANUAL FlexRay-TDP-OM-E Rev A 13 3. Touch a Channel, Memory, or Math trace to open a pop-up dialog that displays a shortcut to the Dec

Page 6 - The TD Series Software

Data Selection – This pop-up dialog allows you select the channel or other source for decoding. Decode Setup Shortcut Button – This provides quic

Page 7

OPERATOR’S MANUAL FlexRay-TDP-OM-E Rev A 15 View Table Checkbox – Checking this box turns the Table ON. Un-checking it turns the Table OFF. Note:

Page 8 - FlexRay Physical Layer

Decode Setup Detail The FlexRay Decode Setup Right-Hand Dialogs (which are contained in the Decode Setup dialog box when FlexRay is selected as the

Page 9

OPERATOR’S MANUAL Protocol Results Table The protocol results table provides a quick and easy way to understand all of your FlexRay data as decoded by

Page 10 - Trigger Setup Detail

Searching for Messages There are several ways to search for specific messages. 1. Touch the decoded waveform to open a pop-up dialog OR 2. T

Page 11 - 11

OPERATOR’S MANUAL Eye Diagram and Mask Test Setup Detail The Left Hand side of the FlexRay Physical Layer tab has all the settings for Eye Diagram Mas

Page 12 - Decode and Decode Setup

 LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY 10977–6499 Tel: (845) 578 6020, Fax: (845) 578-5985 Internet: www.lecroy.com © 2008

Page 13 - 13

Mask Test Display The FlexRay TDP option allows you to verify signal integrity of the communication channel and corresponding protocol data simulta

Page 14 - Decode Setup Dialog Box

OPERATOR’S MANUAL Physical Layer Measurement Setup Detail The Right Hand side of the FlexRay Physical Layer tab has the settings for physical layer me

Page 15 - 15

Just like other measurement parameters statistical information can be displayed and the results can be shown visually in a histicon directly below

Page 16 - Decode Setup Detail

OPERATOR’S MANUAL Using Cursors Use horizontal cursors to mark locations on the waveform where the time measurement should be done, then read the curs

Page 17 - 17

Maximum – Highest value in the input waveform. Mean – Average of all data values. Minimum – Lowest value in the input waveform. Overshoot Neg

Page 18 - Searching for Messages

OPERATOR’S MANUAL Pass/Fail Analysis with Measurement Parameters Pass/Fail analysis using measurement parameters is quite simple to set up and quite p

Page 19 - 19

Trigger Repeatedly, Save Data to a Hard Drive You may wish to set up your oscilloscope to capture a short or long memory acquisition for a certain

Page 20 - Mask Test Display

OPERATOR’S MANUAL FlexRay-TDP-OM-E Rev A 27 2. In the Sampling Mode area, select Sequence Mode. Touch the Sequence tab (now showing next to the Ti

Page 21 - 21

6. Display an individual segment separately from the main channel display by selecting Math Æ Math Setup from the menu bar. Now, choose a math tra

Page 22 - CONTROLLER PERFORMANCE

OPERATOR’S MANUAL FlexRay-TDP-OM-E Rev A 29 8. Conserve display space, by turning off the Channel and selecting only the segment you wish to view

Page 23 - 23

OPERATOR’S MANUAL FlexRay-TDP=OM-E Rev A iii TABLE OF CONTENTS INTRODUCTION...

Page 24 - Measurement Gating

30 FlexRay-TDP-OM-E Rev A APPENDIX A – FLEXRAYBUS TDP AND TD SPECIFICATIONS FlexRaybus TDP Definition Protocol Setup S

Page 25 - 25

OPERATOR’S MANUAL FlexRay-TDP-OM-E Rev A 31 Trigger Capability Format Hexadecimal or Binary for Frame ID Decimal for Cycle Count Trigger Setup

Page 26 - Sequence Mode

32 FlexRay-TDP-OM-E Rev A FlexRaybus TD Definition Protocol Setup Includes all Decode, Trigger and Search functionali

Page 27 - 27

4 FlexRay-TDP-OM-E Rev A INTRODUCTION Several communication protocol types are used in automotive applications. They are use

Page 28 - FlexRay-TDP-OM-E Rev A

OPERATOR’S MANUAL The TDP Series Software The TDP option adds the following capability to the LeCroy oscilloscope software user interface dialogs: 1.

Page 29

The TD Series Software The TD option adds the following capability to the LeCroy oscilloscope software user interface dialogs: 1. Serial Trigger

Page 30 - FlexRaybus TDP

OPERATOR’S MANUAL The D Series Software The D option adds the following capability to the LeCroy oscilloscope software user interface dialogs: 1. Se

Page 31 - 31

8 FlexRay-TDP-OM-E Rev A TECHNICAL OVERVIEW OF D, TD, AND TDP OPTIONS LeCroy’s offering of FlexRay trigger, decode and physi

Page 32 - FlexRaybus TD

OPERATOR’S MANUAL USING THE TRIGGER, DECODE AND PHYSICAL LAYER TOOLSETS FlexRay Triggering FlexRay triggering is easily accessible in a variety of way

Commentaires sur ces manuels

Pas de commentaire