Introduction
Teledyne LeCroy's PCIe 2.0 (Gen2) mid-bus probe supports quick
and easy probing at data rates up to 5 GT/s through a simple probe
footprint designed into the PCB.
Mid-bus probes are used by system designers to probe embedded
bus signals (e.g., for serial data buses that run between chips on a
single circuit board) or simply as a convenient means to access
bus signals with a probe connector. The probe is easily attached to
an retention module mounted on top of a mid--bus footprint that is
laid out on the target test system board.
The Teledyne LeCroy PCIe 2.0 mid-bus probe uses a universal
retention module consisting of two pieces that can accommodate
both "half size" (PCIe x4 lanes) or "full size" (PCIe x8 lanes)
mid-bus footprints. Two x8 mid-bus probes can be connected to a
Summit T3-16 Analyzer and will support x16 lane widths. These
probes can be used in conjunction with the unique lane swizzling
feature on the Summit analyzers (see section 4 for details), which
allows probe signals to be reorganized logically, to give developers
additional flexibility in PCB layout.
Gen2 Mid-bus Half Size Probe Head
Gen2 Mid-bus Half Size Probe and Components (Reference
clock cable not shown)
Gen2 Mid-Bus Probe
Quick Start for Summit™
Analyzers
Before Starting
Use this document for quick installation and setup. If you
experience problems or need more information, see the
product manuals available at the Teledyne LeCroy web site or
in the Documents folder in the PETracer installation CD.
Components
The Teledyne LeCroy Gen2 mid-bus probe kits have the following
components for Summit T3-16, T3-8 and T28:
•Mid-bus Pod
iPass Y-Cable
Probe head with ribbon cables attached
Reference clock cable
Daisy chain cable (for multiple probe pods)
2-piece universal retention module
The Teledyne LeCroy Gen2 mid-bus probe kit has the following
components for Summit T24:
•Mid-bus Pod
iPass x4-to-x8 straight cable
Probe head with ribbon cables attached
Reference clock cable
Daisy chain cable (for multiple probe pods)
2-piece universal retention module
Power Supply
1
2
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Analyzers

IntroductionTeledyne LeCroy's PCIe 2.0 (Gen2) mid-bus probe supports quick and easy probing at data rates up to 5 GT/s through a simple probe foo

Page 2 - Hardware Installation

3Hardware InstallationTo install the components: 1. Install the universal retention module in the Mid Bus footprint. For further details review the PC

Page 3 - Software Configuration

4Software ConfigurationThe default configuration of the Gen2 Mid-bus Probe Assembly is the (x4 width) configuration. To use Summit Analyzers, you must

Page 4 - Recording Traffic

Trademarks and ServicemarksTeledyne LeCroy and Summit are trademarks of Teledyne LeCroy. Microsoft and Windows are registered trademarks of Microsoft