QPHY-USB3-Tx-Rx Software Option
917719 Rev A 39
S-Parameter Files Path
This variable allows the user to specify the path on the oscilloscope that contains the S-Parameter files used for
emulation and/or de-embedding. The default for this variable is D:\Applications\EyeDr\USB3.
SSC
This variable allows the user to specify whether or not Spread Spectrum Clocking (SSC) is enabled on the
Product Under Test. The SigTest Average UI test has different limits based on whether or not SSC is enabled. By
setting this variable, the correct limit for this test can be used. Select Enabled if Spread Spectrum Clocking is
enabled, otherwise select Disabled. The default is Enabled because SSC is required by the USB 3.0
Specification.
Stop On Test to review results
This variable gives the user the option to enable Stop on Test mode. When set to Yes, the testing pauses after
each test allowing the user to review the results. The setup is saved so oscilloscope settings can be modified by
the user. When execution is resumed, the setup is recalled. Note that any new acquisition completed while the
testing is paused may cause the testing to misbehave. The default value for this variable is No.
Test Mode
This variable allows the user to decide whether the tests should be run on newly acquired data or if previously
saved waveforms should be used. The choices for this variable are Acquire New Data and Use Saved Data. If
Use Saved Data is selected, the waveforms are recalled from the location specified in the Saved Waveform
Path variable. The default value for this variable is Acquire New Data.
Use PeRT3
This variable allows the users to select if they would like QualiPHY to automate the PeRT
3
to configure the
Product under test for each test. If this variable is set to No, the user must have the ability to stimulate their
Product under test to transmit the required test patterns for transmitter testing. The default setting for this variable
is No.
Use RF Switch
This variable allows the users to specify whether or not they have an RF Switch. If this variable is set to Yes, the
oscilloscope communicates with the RF Switch and makes the required connections without any user interaction.
If this variable is set to No, the user must connect their signals when prompted. The default value for this
variable is No.
PeRT3 Setup
PeRT3 Hostname or IP Address
This variable allows the user to enter the hostname or IP Address of the PeRT3 Server (the machine that the
PeRT
3
is connected to via USB). If QualiPHY is running from a remote PC and not from the oscilloscope,
localhost refers to the oscilloscope. The default value for this variable is localhost.
PeRT3 SSC Enabled
This variable allows the user to enable SSC on the PeRT
3
’s clock output. This is required for receiver testing. The
default for this variable is Yes.
Transmitter Tests
Deskew measure mode
This variable allows the user to select the method for deskewing their cables. The choices for this variable are
Wizard Method and “User Defined. Wizard Measured is used to launch the automated deskew measurement.
User Defined is used if the user would like to set the Deskew value in picoseconds variable when the deskew
value is already known. The default value for this variable is Wizard Method.