6 917719 Rev A
INTRODUCTION
QPHY-USB3-Tx -Rx is a software package designed to capture, analyze, and report measurements in
conformance with SuperSpeed USB electrical specification standard. A copy of the specification can be found at
www.usb.org.
Compatibility
QPHY-USB3-Tx -Rx is a software option compatible with the following LeCroy X-Stream oscilloscopes:
WM813Zi, SDA813Zi, DDA813Zi (4x40 GS/s, 2x80GS/s) and higher bandwidth equivalents.
SDA II and Eye Doctor II software is required.
The TF-USB3 test fixture set is required for QPHY-USB3-Tx-Rx. This fixture set includes an A-Plug, A-Receptacle
and B-Receptacle fixtures. The Tx+, Tx-, Rx+ and Rx- signals are routed via low loss traces to SSMP connectors.
Eight 2 inch SSMP to SMA cables are provided with the TF -USB3 kit.
Figure 1 - TF-USB3 Fixture Set
Additional Options Equipment Available from LeCroy
Eagle PeRT
3
System (1 channel) – PER-R006-S01-X
o Eagle Receiver Tolerance Test Suite – PER-R006-008-A
o Eagle USB 3.0 Receiver Test Suite – USB-R006-001-A
Keithley S46 RF-Microwave Switch System with 8 SPDT Relays – RF-Switch-8-SPDT
Pair of +/- 1ps phase matched cables (8 inches) – Matched-SMA-Cables-8inch-Pair
Pair of +/- 1ps phase matched cables (12 inches) – Matched-SMA-Cables-12inch-Pair
Pair of +/- 1ps phase matched cables (18 inches) – Matched-SMA-Cables-18inch-Pair
Pair of +/- 1ps phase matched cables (24 inches) – Matched-SMA-Cables-24inch-Pair
GPIB Host Option for LeCroy Oscilloscope – GPIB-HOST