30 FlexRay-TDP-OM-E Rev A
APPENDIX A – FLEXRAYBUS TDP AND TD SPECIFICATIONS
FlexRaybus TDP
Definition
Protocol Setup
Select BitRate (2.5, 5 or 10 Mb/s)
Select FlexRay Channel A or Channel B
Decode Capability
Format
All decoding is hexadecimal except for Cycle Count which is decoded using a decimal format
Decode Setup
Two threshold definitions required. Default is to Percent amplitude.
Select BitRate.
Select FlexRay Chanel A or Channel B
Decode Input
Any analog Channel, Memory or Math trace.
# of Decoded Waveforms
Up to 4 buses may be decoded at one time. In addition, zooms can be displayed (with decoded
information).
Location
Overlaid over DATA waveform, on Grid.
(Note: Use multi-grid if there is more than one decoder ON)
Visual Aid
Color Coding for TSS, FSS, Frame Qualifiers, Slot ID, Payload Length, Header CRC, Cycle
Count, Data, BSS, Payload CRC and FES
Decode information is intelligently annotated based on timebase setting.