Teledyne-lecroy Serial Data Debug Solutions Manuel d'utilisateur Page 138

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 204
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 137
Serial Data Debug Solutions
919586 RevA
BRIEF LP TIMING TEST DESCRIPTIONS
With LP Timing selected in the Category field, the following Measure values are available:
TLP-PER-Data-500, TLP-PER-Data-930, TLP-PULSE-Data-500, TLP-PULSE-Data-930, FIRST-TLP-PULSE-Data-
500, FIRST-TLP-PULSE-Data-930, LAST-TLP-PULSE-Data-500, and LAST-TLP-PULSE-Data-930.
Name
Purpose
TLP-PER-Data-500
To verify that the period (TLP-PER-TX) of the DUT’s Data Lane LP transmitter
XOR Clock is within the conformance limits.
TLP-PER-Data-930
TLP-PULSE-Data-500
To verify that the pulse width (TLP-PULSE-TX) of the DUT’s Data Lane LP
transmitter XOR Clock is within the conformance limits.
TLP-PULSE-Data-930
FIRST-TLP-PULSE-Data-500
FIRST-TLP-PULSE-Data-930
LAST-TLP-PULSE-Data-500
LAST-TLP-PULSE-Data-930
BRIEF LP SLEW RATE TEST DESCRIPTIONS
With LP Slew Rate selected in the Category field, the following Measure values are available:
SR-MAX-Dp, SR-MAX-Dn, SR-MAX-CLKp, SR-MAX-CLKn, SR-FALL-MIN-Dp, SR-FALL-MIN-Dn, SR-FALL-
MIN-CLKp, SR-FALL-MIN-CLKn, SR-RISE-400-700-MIN-Dp, SR-RISE-400-700-MIN-Dn, SR-RISE-400-700-
MIN-CLKp, SR-RISE-400-700-MIN-CLKn, SR-RISE-700-930-MIN-Dp, SR-RISE-700-930-MIN-Dn, SR-RISE-
700-930-MIN-CLKp, and SSR-RISE-700-930-MIN-CLKn.
Name
Purpose
SR-MAX-Dp
To verify that the Slew Rate (δV/δtSR) of the DUT’s Data & Clock Lanes LP
transmitter is within the conformance limits, for specific capacitive loading
conditions.
SR-MAX-Dn
SR-MAX-CLKp
SR-MAX-CLKn
SR-FALL-MIN-Dp
SR-FALL-MIN-Dn
SR-FALL-MIN-CLKp
SR-FALL-MIN-CLKn
SR-RISE-400-700-MIN-Dp
SR-RISE-400-700-MIN-Dn
SR-RISE-400-700-MIN-CLKp
SR-RISE-400-700-MIN-CLKn
SR-RISE-700-930-MIN-Dp
SR-RISE-700-930-MIN-Dn
Vue de la page 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 203 204

Commentaires sur ces manuels

Pas de commentaire