Operator's Manual
919586 RevA
35
Delta Delay - Time between the 50% crossing of the first transition of two waveforms.
Delta Time @ Level - Time between selectable levels of two waveforms.
Note: Delta Time @ Level is not available on WaveSurfer Series oscilloscopes.
Delta Trig Time - The time from last trigger to this trigger (usually used in Sequence mode).
Fall (90-10), Fall 80-20, Fall@Level - Transition time on the falling edge. Three selections are available
for the user to determine at which vertical level the measurement is made.
Note: Fall@Level is not available on WaveSurfer Series oscilloscopes.
Maximum - Highest value in the input waveform.
Mean - Average of all data values.
Minimum - Lowest value in the input waveform.
Overshoot Negative - Overshoot following a falling edge.
Overshoot Positive - Overshoot following a rising edge.
Peak to Peak - Difference between the Maximum and Minimum data values.