QPHY-PCIE Operator’s Manual
Variations exist for different source configurations: differential inputs on Input A or Input B, and
single inputs on Input A or Input B.
Signal Quality Test (CEM), System
This configuration is meant to run all of the transmitter tests on a PCIe System board. All the
variables are set to default. The limit set is use is PCIe 2.1. Both 2.5Gbps and 5.0Gbps Signal
Quality tests are run. Variations exist for different source configurations: differential inputs on
Input A or Input B, and single inputs on Input A or Input B.
QPHY-PCIE Test Descriptions
2.5 GT/s Signal Quality Tests
These tests use the “PCIe Compliance” Signal Type selection from the SDA II analysis software.
When “PCIe Compliance” is selected, SDA II uses the SigTest DLL in the background to
generate the Eye Diagrams and the Jitter results. This can only be done using 2.5GT/s signals.
Mean Unit Interval
Max Unit Interval
Min Unit Interval
Min Time Between Crossovers
Data Rate
Per Edge RMS Jitter
Mean Median to Peak Jitter
Max Median to Peak Jitter
Min Median to Peak Jitter
Mean peak-to-peak jitter
Max peak-to-peak jitter
Min peak-to-peak jitter
Minimum transition eye voltage
Maximum transition eye voltage
Minimum non-transition eye voltage
Maximum non-transition eye voltage
Minimum transition eye voltage margin above eye
Minimum transition eye voltage margin below eye
Minimum non-transition eye voltage margin above eye
Minimum non-transition eye voltage margin above eye
Transition eye mask violations
Non-transition eye mask violations
Minimum Eye Width
Differential peak to peak voltage